Chapter 3: Network Design Considerations
Table of Contents
Section titled “Table of Contents”- Goal
- AI/ML Workload Processing and Fabric Types
- Training Data Center Architecture
- GPU-to-Leaf Connectivity
- Rack Design
- Scheduled Fabric and VOQ
- Topology Choices
- Inference Data Center Architecture
- Multi-Planar Scale-Out Architecture
- Additional Design Notes
- Chapter Summary
- Key Terms
- Questions
- Answers
- References
This chapter explains the major physical and logical design choices for AI data center networks.
The core idea is:
AI data center design is a trade-off between performance, cost, reliability, scalability, power, cooling, and operational complexity.
The chapter focuses on these topics:
- Storage, training, and inference fabrics
- Rail-Optimized Design, ROD, and Rail-Unified Design, RUD
- GPU-to-leaf connectivity and rail design
- Rack placement for leaf switches: ToR, MoR, and EoR
- Clos, Dragonfly, and Torus topologies
- Scheduled fabric and virtual output queueing
- Multi-planar scale-out architectures
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
classDef server fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef storage fill:#173f32,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef training fill:#232323,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef inference fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef note fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
subgraph Host["AI/ML Server Boundary"]
S[GPU Server<br/>CPU + GPU + NIC + Storage Ports]:::server
end
subgraph Fabrics["Network Fabrics Around the Server"]
SF[Storage Fabric<br/>datasets / checkpoints]:::storage
TF[Training Fabric<br/>backend RDMA / collectives]:::training
IF[Inference Fabric<br/>frontend serving traffic]:::inference
end
SP[Large data lake<br/>NVMe / object / parallel FS]:::note
TP[Distributed training job<br/>AllReduce / AllGather / ReduceScatter]:::note
IP[Users and applications<br/>request / response / TTFT]:::note
S <-->|checkpoint read/write| SF
S <-->|GPU-to-GPU east-west| TF
S <-->|API and serving path| IF
SF --> SP
TF --> TP
IF --> IP
AI/ML Workload Processing and Fabric Types
Section titled “AI/ML Workload Processing and Fabric Types”AI/ML workload processing follows three broad stages:
- Data gathering and preprocessing
- Model selection and training
- Deployment and monitoring
Each stage stresses the network differently. Storage movement, training communication, and inference serving are often separated into different fabrics or at least different design domains.
| Fabric | Main Role | Typical Traffic | Main Design Concern |
|---|---|---|---|
| Storage fabric | Move data sets and checkpoints | Server-to-storage, checkpoint read/write | Low latency, high throughput, low loss |
| Training fabric | GPU-to-GPU communication | East-west RDMA, collectives | Bandwidth, latency, congestion control |
| Inference fabric | Serve trained models | User request/response, API traffic | Latency, throughput, reliability |
Storage Fabric
Section titled “Storage Fabric”The storage fabric stores gathered and preprocessed data. Small data sets may live inside the training cluster, but large data sets normally require dedicated storage infrastructure.
Important requirements:
- High throughput for data ingestion and checkpointing
- Low latency for storage access
- Low packet loss or lossless behavior
- Support for InfiniBand or Ethernet with RoCEv2
- Three-stage or five-stage Clos when Ethernet is used
Training Fabric
Section titled “Training Fabric”The training fabric is the backend network for GPU clusters. It supports distributed training, collective communication, and east-west traffic between GPU servers.
Training fabric design is the main focus of this chapter because it directly affects GPU utilization and training time.
Inference Fabric
Section titled “Inference Fabric”The inference fabric is the production network where trained models answer requests. Its architecture is usually closer to enterprise, cloud, or telco data center networking.
Inference designs usually do not need strict rail alignment unless the model is very large and requires multi-node inference with RDMA.
Training Data Center Architecture
Section titled “Training Data Center Architecture”Training data center architecture must balance several competing goals.
Design Goals
Section titled “Design Goals”| Goal | Meaning |
|---|---|
| Performance | Keep GPU-to-GPU communication fast enough that GPUs do not wait on the network |
| Cost efficiency | Control NIC, optics, switch port, cabling, and facility cost |
| Reliability | Isolate failures and avoid taking down many GPUs with one failed component |
| Scalability | Add more GPUs, rows, blocks, or fabrics without redesigning everything |
The chapter repeatedly returns to this point:
A high-performance AI fabric is not just a bigger data center network. It must be designed around GPU topology, NIC placement, collective communication, and physical constraints.
GPU Server Network Ports
Section titled “GPU Server Network Ports”GPU servers commonly include different classes of ports:
- GPU-facing NIC ports for training traffic
- CPU or host ports for frontend and control traffic
- Storage-mapped ports for NVMe or storage access
Modern GPU servers such as NVIDIA A100/H100-based systems often contain 8 GPUs. Each GPU may be mapped to one or more NICs, but a common cost-conscious design uses one NIC per GPU.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart LR
classDef gpu fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef fabric fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef io fill:#232323,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef host fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
subgraph Server["8-GPU Training Server"]
direction TB
CPU[CPU Complex<br/>control, data loader, host stack]:::host
NV[NVLink / NVSwitch<br/>scale-up GPU fabric]:::fabric
subgraph GPUs["GPU + east-west NIC pairs"]
direction LR
G0[GPU0<br/>NIC0]:::gpu
G1[GPU1<br/>NIC1]:::gpu
G2[GPU2<br/>NIC2]:::gpu
G3[GPU3<br/>NIC3]:::gpu
G4[GPU4<br/>NIC4]:::gpu
G5[GPU5<br/>NIC5]:::gpu
G6[GPU6<br/>NIC6]:::gpu
G7[GPU7<br/>NIC7]:::gpu
end
NS[north-south NIC<br/>frontend / storage / management]:::io
end
CPU --- NV
NV --- G0
NV --- G1
NV --- G2
NV --- G3
NV --- G4
NV --- G5
NV --- G6
NV --- G7
CPU --- NS
G0 -->|400G/800G rail| EWF[east-west training fabric]:::fabric
NS -->|customer / storage / OOB| NSF[north-south networks]:::io
Inside a server, GPU-to-GPU communication can use high-bandwidth internal fabrics such as NVLink or NVSwitch. Once a workload spans more GPUs than fit in one server, the traffic becomes east-west data center traffic.
GPU-to-Leaf Connectivity
Section titled “GPU-to-Leaf Connectivity”The chapter compares two major GPU-to-leaf design styles:
| Design | Connectivity Model | Main Benefit | Main Trade-Off |
|---|---|---|---|
| ROD | One GPU/NIC connects to one dedicated rail/leaf | High performance and rail isolation | More cables, more leaf connections |
| RUD | Multiple GPUs connect to one leaf | Simpler cabling and potentially lower cost | More shared fate and path complexity |
Rail-Optimized Design, ROD
Section titled “Rail-Optimized Design, ROD”In Rail-Optimized Design, each GPU/NIC in a server maps to a separate rail.
Example for an 8-GPU server:
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart LR
classDef gpu fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef rail0 fill:#173f32,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef rail1 fill:#5a3520,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef rail7 fill:#5a3520,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef switch fill:#173f32,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
subgraph SA["Server A"]
direction TB
A0[GPU0 / NIC0]:::gpu
A1[GPU1 / NIC1]:::gpu
A2[GPU2 / NIC2]:::gpu
AX[...]
A7[GPU7 / NIC7]:::gpu
end
subgraph RF["Rail-Optimized Leaf Layer"]
direction TB
R0[Rail 0<br/>Leaf 0]:::rail0
R1[Rail 1<br/>Leaf 1]:::rail1
R2[Rail 2<br/>Leaf 2]:::switch
RX[...]:::switch
R7[Rail 7<br/>Leaf 7]:::rail7
end
subgraph SB["Server B"]
direction TB
B0[GPU0 / NIC0]:::gpu
B1[GPU1 / NIC1]:::gpu
B2[GPU2 / NIC2]:::gpu
BX[...]
B7[GPU7 / NIC7]:::gpu
end
A0 <-->|same GPU index| R0
R0 <-->|one-hop rail path| B0
A1 <--> R1
R1 <--> B1
A2 <--> R2
R2 <--> B2
AX ~~~ RX
RX ~~~ BX
A7 <--> R7
R7 <--> B7
Why ROD is attractive:
- Each GPU has a predictable network path.
- Rail-local communication can be one hop.
- Faults can be isolated by rail.
- NCCL rings and trees can be aligned with GPU/NIC topology.
- It fits high-throughput AllReduce, AllGather, and ReduceScatter patterns.
Rows, Stripes, and 1:1 Oversubscription
Section titled “Rows, Stripes, and 1:1 Oversubscription”A set of 8 leaf switches connecting to the 8 GPU positions across servers is called a row or stripe.
For example:
- Leaf 0 connects GPU0/NIC0 from many servers.
- Leaf 1 connects GPU1/NIC1 from many servers.
- Leaf 7 connects GPU7/NIC7 from many servers.
With a 64 x 400G leaf switch:
| Port Use | Count | Bandwidth |
|---|---|---|
| Server-facing downlinks | 32 | 12.8 Tbps |
| Spine-facing uplinks | 32 | 12.8 Tbps |
| Oversubscription | - | 1:1 |
This 1:1 ratio is important because training traffic can drive GPU NICs at very high utilization.
Intra-Rail vs. Inter-Rail Communication
Section titled “Intra-Rail vs. Inter-Rail Communication”ROD gives the best latency when traffic stays within the same rail.
| Traffic Type | Example | Path | Latency |
|---|---|---|---|
| Intra-rail | Server A GPU0 to Server B GPU0 | Leaf only | Lower |
| Inter-rail | Server A GPU0 to Server B GPU3 | Leaf - spine - leaf | Higher |
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart LR
classDef gpu fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef leaf fill:#232323,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef spine fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef fast fill:#173f32,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef slow fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
A0[Server A<br/>GPU0 / NIC0]:::gpu
L0[Leaf 0<br/>Rail 0]:::leaf
B0[Server B<br/>GPU0 / NIC0]:::gpu
L3[Leaf 3<br/>Rail 3]:::leaf
SP[Spine Layer<br/>rail transition point]:::spine
B3[Server B<br/>GPU3 / NIC3]:::gpu
A0 ==>|intra-rail: same GPU index, one leaf hop| L0
L0 ==>|fast path| B0
A0 -.->|inter-rail: GPU0 to GPU3| L0
L0 -.->|extra hop| SP
SP -.->|rail change| L3
L3 -.->|two-hop fabric path| B3
Intra-rail communication is the fast path. Inter-rail communication usually needs the spine layer and doubles the number of network hops.
Scaling with Three-Stage Clos
Section titled “Scaling with Three-Stage Clos”For a 256-GPU cluster:
- 32 servers
- 8 GPUs per server
- 8 leaf switches
- 4 spine switches
- 64 x 400G switches
For a 512-GPU cluster:
- 64 servers
- 16 leaf switches
- 8 spine switches
- Two rows of rail-optimized leaf switches
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
classDef server fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef leaf fill:#232323,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef spine fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef note fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
subgraph R1["Row / Stripe 1: 256 GPUs"]
direction TB
S1[32 servers<br/>8 GPUs each]:::server
L1[8 rail leaves<br/>Leaf0 ... Leaf7]:::leaf
S1 -->|256 x GPU links| L1
end
subgraph R2["Row / Stripe 2: +256 GPUs"]
direction TB
S2[32 more servers<br/>8 GPUs each]:::server
L2[8 more rail leaves<br/>Leaf0 ... Leaf7]:::leaf
S2 -->|256 x GPU links| L2
end
SP[Spine Layer<br/>connect rows and inter-rail traffic]:::spine
N1[One row: 32 servers = 256 GPUs]:::note
N2[Two rows: 64 servers = 512 GPUs]:::note
L1 <-->|uplinks| SP
L2 <-->|uplinks| SP
L1 -.-> N1
L2 -.-> N2
To scale further, designers can either add more spines or use chassis-based spines with higher port density. Adding many standalone spines can create management and load-balancing complexity.
Scaling with Five-Stage and Seven-Stage Clos
Section titled “Scaling with Five-Stage and Seven-Stage Clos”Very large AI clusters may target 32K, 64K, or 128K GPUs. At that scale, a simple three-stage Clos is not enough.
The chapter describes larger designs using:
- Five-stage Clos: leaf - spine - super-spine - spine - leaf
- Seven-stage Clos for even larger fabrics
- Blocks or bricks connected through super-spines
- Chassis-based spine or super-spine systems
- Controlled oversubscription at upper layers
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart LR
classDef endpoint fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef leaf fill:#232323,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef spine fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef super fill:#3b2f20,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef risk fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
A[GPU Server<br/>Block A]:::endpoint
L1[Leaf]:::leaf
S1[Spine]:::spine
SS[Super-spine<br/>block-to-block scale layer]:::super
S2[Spine]:::spine
L2[Leaf]:::leaf
B[GPU Server<br/>Block B]:::endpoint
A <--> L1
L1 <--> S1
S1 <--> SS
SS <--> S2
S2 <--> L2
L2 <--> B
H[Each added stage increases<br/>hop count, optics, cabling, and congestion risk]:::risk
SS -.->|upper-layer oversubscription often appears here| H
The chapter notes that some designs evaluate oversubscription at the super-spine layer, potentially up to high ratios. The trade-off is clear: higher oversubscription reduces cost and port count, but increases the likelihood of congestion and requires stronger congestion control such as DCQCN, ECN, and PFC.
Example: 32K GPU ROD over Multi-Stage Clos
Section titled “Example: 32K GPU ROD over Multi-Stage Clos”The following example connects the ROD mental model to a 32K-class Clos design.
Assume one ROD pod contains:
- 32 GPU servers
- 8 GPUs per server
- 8 rail leaves per pod
- 256 GPUs per pod
Then:
128 pods x 256 GPUs per pod = 32,768 GPUsIn this model, each pod preserves the ROD rule internally: GPU0/NIC0 maps to Rail 0, GPU1/NIC1 maps to Rail 1, and so on. The multi-stage Clos fabric then connects many such ROD pods through spine and super-spine layers.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
classDef server fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef rail fill:#173f32,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef pod fill:#5a3520,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef spine fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef super fill:#3b2f20,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef note fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
subgraph T3["Tier 3: super-spine layer"]
direction LR
SS1[Super-spine 1]:::super
SS2[Super-spine 2]:::super
SSX[...]:::super
SSN[Super-spine N]:::super
end
subgraph T2["Tier 2: spine groups"]
direction LR
SP1[Spine group 1]:::spine
SP2[Spine group 2]:::spine
SP3[Spine group 3]:::spine
SP4[Spine group 4]:::spine
end
subgraph T1["Tier 1: ROD pod layer"]
direction LR
P1[Pod 001<br/>256 GPUs<br/>32 servers x 8 GPUs]:::pod
P2[Pod 002<br/>256 GPUs]:::pod
P3[Pod 003<br/>256 GPUs]:::pod
PX[...]:::pod
P128[Pod 128<br/>256 GPUs]:::pod
end
subgraph RAIL["Inside one ROD pod"]
direction TB
S[32 x 8-GPU servers]:::server
R0[Rail 0 leaf<br/>GPU0 / NIC0]:::rail
R1[Rail 1 leaf<br/>GPU1 / NIC1]:::rail
R2[Rail 2 leaf<br/>GPU2 / NIC2]:::rail
R3[Rail 3 leaf<br/>GPU3 / NIC3]:::rail
R4[Rail 4 leaf<br/>GPU4 / NIC4]:::rail
R5[Rail 5 leaf<br/>GPU5 / NIC5]:::rail
R6[Rail 6 leaf<br/>GPU6 / NIC6]:::rail
R7[Rail 7 leaf<br/>GPU7 / NIC7]:::rail
end
M[32K-class example:<br/>128 pods x 256 GPUs = 32,768 GPUs]:::note
SS1 --- SP1
SS1 --- SP2
SS1 --- SP3
SS1 --- SP4
SS2 --- SP1
SS2 --- SP2
SS2 --- SP3
SS2 --- SP4
SSN --- SP1
SSN --- SP2
SSN --- SP3
SSN --- SP4
SP1 --- P1
SP1 --- P2
SP1 --- P3
SP1 --- P128
SP2 --- P1
SP2 --- P2
SP2 --- P3
SP2 --- P128
SP3 --- P1
SP3 --- P2
SP3 --- P3
SP3 --- P128
SP4 --- P1
SP4 --- P2
SP4 --- P3
SP4 --- P128
S -.-> R0
S -.-> R1
S -.-> R2
S -.-> R3
S -.-> R4
S -.-> R5
S -.-> R6
S -.-> R7
P1 -.->|internal ROD structure| RAIL
T1 -.->|pod count drives GPU scale| M
This is only a conceptual scaling model. A real design still needs concrete switch radix, oversubscription targets, cable reach, optics budget, failure domains, ECMP or adaptive load balancing behavior, and workload placement policy.
Rail-Only Design
Section titled “Rail-Only Design”Rail-only design removes inter-rail communication from the external fabric.
The basic idea:
- Same-number GPUs communicate across the external rail fabric.
- Different GPU numbers communicate through the server’s internal GPU switch, such as NVSwitch.
- The external fabric does not need to provide rail-to-rail paths.
Benefits:
- Lower network cost
- Simpler rail fault isolation
- Easier troubleshooting when workloads do not need inter-rail fabric communication
Limitations:
- Depends heavily on workload behavior
- Inter-rail needs must be handled inside the server
- May not fit all collective communication patterns
- Adoption and best practices are still evolving
Rail-Unified Design, RUD
Section titled “Rail-Unified Design, RUD”In Rail-Unified Design, multiple GPUs from the same server connect to the same leaf.
Examples:
- 8 GPUs connect to one leaf
- 4 GPUs connect to one leaf and 4 GPUs connect to another leaf
- Rails are grouped rather than strictly separated one GPU per leaf
RUD can reduce cabling complexity, but it requires the fabric to segregate rail traffic carefully.
Important implications:
- A single leaf can become a larger failure domain.
- Deterministic path forwarding becomes more important.
- Some traffic can remain one hop, but other traffic must cross the spine.
- It may be attractive when using larger chassis-based switches or when cabling simplicity matters more than strict rail isolation.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
classDef gpu fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef leaf fill:#232323,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef spine fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef risk fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
subgraph Server["Server: multiple GPU rails share fewer leaves"]
direction LR
G0[GPU0]:::gpu
G1[GPU1]:::gpu
G2[GPU2]:::gpu
G3[GPU3]:::gpu
G4[GPU4]:::gpu
G5[GPU5]:::gpu
G6[GPU6]:::gpu
G7[GPU7]:::gpu
end
subgraph Leaves["Rail-Unified Leaf Layer"]
L0[Leaf A<br/>rails 0-3]:::leaf
L1[Leaf B<br/>rails 4-7]:::leaf
end
SP[Spine Layer<br/>needed for some cross-leaf paths]:::spine
FD[Failure domain grows:<br/>one leaf can affect several GPUs]:::risk
G0 --> L0
G1 --> L0
G2 --> L0
G3 --> L0
G4 --> L1
G5 --> L1
G6 --> L1
G7 --> L1
L0 <--> SP
SP <--> L1
L0 -.->|shared fate| FD
L1 -.->|shared fate| FD
Example: 32K GPU RUD over Multi-Stage Clos
Section titled “Example: 32K GPU RUD over Multi-Stage Clos”The same 32K-class scale can also be drawn with a RUD-style pod. The pod size does not have to change:
128 pods x 256 GPUs per pod = 32,768 GPUsThe difference is inside the pod. Instead of mapping each GPU/NIC position to its own rail leaf, multiple GPU/NIC positions share fewer leaf groups. The example below uses two leaf groups per pod:
- Leaf group A carries GPU0-GPU3 traffic.
- Leaf group B carries GPU4-GPU7 traffic.
- Spine connectivity is still used to connect pods into the larger multi-stage Clos fabric.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
classDef server fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef leaf fill:#232323,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef pod fill:#5a3520,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef spine fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef super fill:#3b2f20,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef risk fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef note fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
subgraph T3["Tier 3: super-spine layer"]
direction LR
SS1[Super-spine 1]:::super
SS2[Super-spine 2]:::super
SSX[...]:::super
SSN[Super-spine N]:::super
end
subgraph T2["Tier 2: spine groups"]
direction LR
SP1[Spine group 1]:::spine
SP2[Spine group 2]:::spine
SP3[Spine group 3]:::spine
SP4[Spine group 4]:::spine
end
subgraph T1["Tier 1: RUD pod layer"]
direction LR
P1[Pod 001<br/>256 GPUs<br/>32 servers x 8 GPUs]:::pod
P2[Pod 002<br/>256 GPUs]:::pod
P3[Pod 003<br/>256 GPUs]:::pod
PX[...]:::pod
P128[Pod 128<br/>256 GPUs]:::pod
end
subgraph RUD["Inside one RUD pod"]
direction TB
S[32 x 8-GPU servers]:::server
GA[Leaf group A<br/>GPU0-GPU3 / NIC0-NIC3]:::leaf
GB[Leaf group B<br/>GPU4-GPU7 / NIC4-NIC7]:::leaf
DPF[Deterministic path forwarding<br/>separates rail traffic inside shared leaves]:::note
FD[Shared fate grows:<br/>one leaf group can affect multiple GPU positions]:::risk
end
M[32K-class example:<br/>128 pods x 256 GPUs = 32,768 GPUs]:::risk
SS1 --- SP1
SS1 --- SP2
SS1 --- SP3
SS1 --- SP4
SS2 --- SP1
SS2 --- SP2
SS2 --- SP3
SS2 --- SP4
SSN --- SP1
SSN --- SP2
SSN --- SP3
SSN --- SP4
SP1 --- P1
SP1 --- P2
SP1 --- P3
SP1 --- P128
SP2 --- P1
SP2 --- P2
SP2 --- P3
SP2 --- P128
SP3 --- P1
SP3 --- P2
SP3 --- P3
SP3 --- P128
SP4 --- P1
SP4 --- P2
SP4 --- P3
SP4 --- P128
S -.->|GPU0-GPU3| GA
S -.->|GPU4-GPU7| GB
GA -.-> DPF
GB -.-> DPF
GA -.-> FD
GB -.-> FD
P1 -.->|internal RUD structure| RUD
T1 -.->|same pod count, different internal leaf model| M
This RUD view is useful for comparing design trade-offs against the ROD example. Both examples can represent the same 32K-class GPU count, but RUD reduces the number of distinct rail-leaf groups inside a pod and therefore increases the importance of deterministic forwarding, failure-domain analysis, and congestion isolation.
Rack Design
Section titled “Rack Design”Rack design is not a cosmetic detail in AI data centers. It affects:
- Cable length
- Rack power budget
- Cooling requirement
- Switch placement
- Failure domain
- Whether DAC, AEC, AOC, or optics are practical
A typical rack is 19 inches wide and 42U tall. The chapter notes that DGX H100-class servers are large and power-dense. Four or five such systems plus network gear can push a rack into a much higher power range than traditional data centers.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
classDef server fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef network fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef cable fill:#5a3520,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef note fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
subgraph TOR["ToR: switch per server rack"]
direction TB
TSW[Leaf switch<br/>inside rack]:::network
TS[GPU servers]:::server
TC[Short local cables<br/>higher rack power/cooling]:::cable
TS --> TSW
TSW --> TC
end
subgraph MOR["MoR: network rack in the middle"]
direction TB
MS1[Left server racks]:::server
MSW[Leaf/spine rack<br/>middle of row]:::network
MS2[Right server racks]:::server
MC[Medium cable length<br/>balanced placement]:::cable
MS1 --> MSW
MS2 --> MSW
MSW --> MC
end
subgraph EOR["EoR: centralized network rack"]
direction TB
ES[Server row]:::server
ESW[Leaf/spine rack<br/>end of row]:::network
EC[Longest cables<br/>lowest server-rack switch power]:::cable
ES --> ESW
ESW --> EC
end
N[Physical design trades cable length<br/>against rack power, cooling, and operations]:::note
TOR -.-> N
MOR -.-> N
EOR -.-> N
Top-of-Rack
Section titled “Top-of-Rack”In a Top-of-Rack, ToR, design, the leaf switch is installed in each server rack.
Benefits:
- Shorter cable runs inside the rack
- Simpler local cabling
- Good fit for RUD
- DAC or AEC may be practical for cost savings
Trade-offs:
- More rack power consumption
- More rack cooling demand
- Switches share the same physical rack environment as servers
- ROD may still require cross-rack cabling because each server connects to multiple leaf switches
Middle-of-Row
Section titled “Middle-of-Row”In a Middle-of-Row, MoR, design, leaf switches are installed in one or more racks near the middle of the server row.
Benefits:
- Server racks do not carry leaf switch power and cooling load
- Cable distances are shorter than EoR
- Leaf and spine switches can be centralized
Trade-offs:
- More cabling across racks
- More network rack space
- Cable lengths vary by server rack position
End-of-Row
Section titled “End-of-Row”In an End-of-Row, EoR, design, leaf switches are installed at one end of the server row.
Benefits:
- Centralized network gear
- Server racks avoid switch power and cooling load
- Operationally familiar in some data center designs
Trade-offs:
- Longest cable runs
- Higher cabling complexity
- More careful planning for optics and cable types
Rack Design Comparison
Section titled “Rack Design Comparison”| Aspect | ToR | MoR | EoR |
|---|---|---|---|
| Leaf location | In each server rack | Middle rack(s) | End rack(s) |
| Server rack power | Higher | Lower | Lower |
| Server rack cooling | Higher | Lower | Lower |
| Cable length | Shorter locally | Medium | Longest |
| Cabling complexity | Lower for local rack, higher for ROD rails | Medium | Higher |
| Best fit | RUD, compact designs | Balanced rows | Centralized network rows |
Scheduled Fabric and VOQ
Section titled “Scheduled Fabric and VOQ”Scheduled fabric is a newer architecture where the fabric behaves more like a distributed chassis.
The concept:
- Leaf switches act like line cards.
- Spine switches act like the backplane.
- Packets arriving at ingress leaves are split into small cells.
- Cells are sprayed across fabric links.
- Egress leaves reassemble cells into packets.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart LR
classDef packet fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef leaf fill:#232323,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef queue fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef cell fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef spine fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef schedule fill:#3b2f20,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
P[Original packet<br/>from GPU server]:::packet
IL[Ingress leaf<br/>line-card role]:::leaf
subgraph IQ["Ingress leaf VOQ state"]
direction TB
Q1[VOQ for egress leaf A]:::queue
Q2[VOQ for egress leaf B]:::queue
Q3[VOQ for egress leaf C]:::queue
SCH[Scheduler chooses<br/>which VOQ sends next]:::schedule
Q1 --> SCH
Q2 --> SCH
Q3 --> SCH
end
subgraph Cells["Cellization"]
direction TB
C1[Fixed-size cell 1]:::cell
C2[Fixed-size cell 2]:::cell
C3[Fixed-size cell 3]:::cell
end
subgraph Fabric["Scheduled fabric: spine acts like a backplane"]
direction TB
SP1[Fabric link / spine 1]:::spine
SP2[Fabric link / spine 2]:::spine
SP3[Fabric link / spine 3]:::spine
end
EL[Egress leaf<br/>packet reassembly]:::leaf
OUT[Rebuilt packet<br/>to destination GPU]:::packet
P --> IL
IL --> Q1
SCH --> C1
SCH --> C2
SCH --> C3
C1 --> SP1
SP1 --> EL
C2 --> SP2
SP2 --> EL
C3 --> SP3
SP3 --> EL
EL --> OUT
The chapter highlights virtual output queueing, VOQ, as a key concept. VOQ maintains separate virtual queues per egress destination so congestion on one output does not block unrelated traffic. Cellization is a related scheduled-fabric technique: packets are divided into fixed-size cells for scheduling across the fabric and then reassembled at the egress leaf.
Benefits:
- Better congestion handling
- Better fabric link utilization
- Reduced head-of-line blocking
- Cell spraying across multiple links
- Potential latency improvement because split/reassembly happens once across the fabric
Constraints:
- Newer architecture
- Vendor and implementation dependence
- Failure handling must be evaluated
- Congestion behavior under real workloads must be tested
- Potential lock-in at the block, brick, or pod level
Topology Choices
Section titled “Topology Choices”Clos is the default topology for most AI data center fabrics. Dragonfly and Torus are useful to understand as alternatives, but they are usually considered for specific HPC-style environments, special placement models, or very controlled traffic patterns rather than general-purpose AI data centers.
| Aspect | Clos / Fat-tree | Dragonfly | Torus |
|---|---|---|---|
| Basic idea | Hierarchical leaf-spine connectivity | Dense intra-group connectivity with inter-group global links | Grid-like connectivity between neighboring nodes or racks |
| Rack-level view | Racks connect upward to spine layers | Racks form groups, and groups are connected through global links | Racks connect directly to nearby racks |
| Path length | Short and predictable | Can be designed to be very short | Depends heavily on location |
| Bandwidth | Can be non-blocking if designed that way | Sensitive to global-link placement | Strong for local traffic, weaker for distant traffic |
| Cost | High | Efficient at very large scale | Relatively low |
| Operational complexity | Lowest | High | High |
| Routing | Standard ECMP/BGP models | Adaptive or global routing is important | Dimension-order or adaptive routing |
| General DC fit | Very high | Low to medium | Low |
| HPC fit | High | Very high | High for specific workloads |
| AI training fit | Most common | Possible, but placement matters | Challenging for large LLM all-to-all patterns |
| Failure handling | Good | Complex | Possible, but operationally complex |
| Cabling | Many uplinks toward spine layers | Global-link management is important | Regular pattern, but placement is constrained |
Clos, also called fat-tree, is the most common data center topology.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
subgraph Spine["Spine Layer"]
SP1["Spine 1"]
SP2["Spine 2"]
SP3["Spine 3"]
SP4["Spine 4"]
end
subgraph Leaf["Leaf / ToR Layer"]
L1["Rack 1 ToR/Leaf"]
L2["Rack 2 ToR/Leaf"]
L3["Rack 3 ToR/Leaf"]
L4["Rack 4 ToR/Leaf"]
end
subgraph Servers["Server Racks"]
R1["Rack 1 Servers / GPUs"]
R2["Rack 2 Servers / GPUs"]
R3["Rack 3 Servers / GPUs"]
R4["Rack 4 Servers / GPUs"]
end
SP1 --- L1
SP1 --- L2
SP1 --- L3
SP1 --- L4
SP2 --- L1
SP2 --- L2
SP2 --- L3
SP2 --- L4
SP3 --- L1
SP3 --- L2
SP3 --- L3
SP3 --- L4
SP4 --- L1
SP4 --- L2
SP4 --- L3
SP4 --- L4
L1 --- R1
L2 --- R2
L3 --- R3
L4 --- R4
Common forms:
- Three-stage Clos: leaf - spine - leaf
- Five-stage Clos: leaf - spine - super-spine - spine - leaf
- Seven-stage Clos for larger fabrics
Why Clos is popular:
- Well understood
- Supports non-blocking designs
- Fits IP and Ethernet operational models
- Provides many equal-cost paths
- Scales by adding stages and higher-radix switches
Main limitations at AI scale:
- More stages mean more hops and more latency.
- Cabling and optics grow quickly.
- Load balancing and congestion control become harder.
- Upper layers may need oversubscription, creating congestion risk.
Dragonfly
Section titled “Dragonfly”Dragonfly is a hierarchical topology where groups, blocks, bricks, or pods connect to each other in a mesh-like structure.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
subgraph G1["Group 1"]
G1R1["Rack/Router 1"]
G1R2["Rack/Router 2"]
G1R3["Rack/Router 3"]
G1R4["Rack/Router 4"]
G1R1 --- G1R2
G1R1 --- G1R3
G1R2 --- G1R4
G1R3 --- G1R4
end
subgraph G2["Group 2"]
G2R1["Rack/Router 1"]
G2R2["Rack/Router 2"]
G2R3["Rack/Router 3"]
G2R4["Rack/Router 4"]
G2R1 --- G2R2
G2R1 --- G2R3
G2R2 --- G2R4
G2R3 --- G2R4
end
subgraph G3["Group 3"]
G3R1["Rack/Router 1"]
G3R2["Rack/Router 2"]
G3R3["Rack/Router 3"]
G3R4["Rack/Router 4"]
G3R1 --- G3R2
G3R1 --- G3R3
G3R2 --- G3R4
G3R3 --- G3R4
end
subgraph G4["Group 4"]
G4R1["Rack/Router 1"]
G4R2["Rack/Router 2"]
G4R3["Rack/Router 3"]
G4R4["Rack/Router 4"]
G4R1 --- G4R2
G4R1 --- G4R3
G4R2 --- G4R4
G4R3 --- G4R4
end
G1R1 === G2R1
G1R2 === G3R1
G1R3 === G4R1
G2R2 === G3R2
G2R3 === G4R2
G3R3 === G4R3
Benefits:
- Lower network diameter than very large multi-stage Clos designs
- Lower latency for some large-cluster communication patterns
- Modular growth by adding groups
- Potentially fewer links than a full multi-stage Clos at large scale
- Fault tolerance through group-level modularity
Trade-offs:
- More complex routing
- More specialized topology management
- Adaptive routing may be needed to avoid congestion
- Not as operationally familiar as Clos in many data centers
Dragonfly can use different intra-group designs, including full-graph inter-group topology or Clos-style intra-group topology.
Torus topology connects nodes to neighbors in one, two, or three dimensions.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
A1["Rack 1"] --- A2["Rack 2"] --- A3["Rack 3"] --- A4["Rack 4"]
B1["Rack 5"] --- B2["Rack 6"] --- B3["Rack 7"] --- B4["Rack 8"]
C1["Rack 9"] --- C2["Rack 10"] --- C3["Rack 11"] --- C4["Rack 12"]
D1["Rack 13"] --- D2["Rack 14"] --- D3["Rack 15"] --- D4["Rack 16"]
A1 --- B1
A2 --- B2
A3 --- B3
A4 --- B4
B1 --- C1
B2 --- C2
B3 --- C3
B4 --- C4
C1 --- D1
C2 --- D2
C3 --- D3
C4 --- D4
A1 -. wrap .- A4
B1 -. wrap .- B4
C1 -. wrap .- C4
D1 -. wrap .- D4
A1 -. wrap .- D1
A2 -. wrap .- D2
A3 -. wrap .- D3
A4 -. wrap .- D4
| Torus Type | Node Connectivity | Mental Model |
|---|---|---|
| 1D torus | Two neighbors | Ring |
| 2D torus | Four neighbors | Grid with wrapped edges |
| 3D torus | Six neighbors | Cube with wrapped edges |
Benefits:
- Cost-effective at high scale due to lower port requirements
- Easy to scale in regular patterns
- Good for nearest-neighbor communication
- Can be used to build rail-like topologies without a traditional spine layer
Limitations:
- Less flexible for arbitrary traffic patterns
- Average latency can be higher for distant nodes
- Routing and failure handling require care
- Application placement matters more
Inference Data Center Architecture
Section titled “Inference Data Center Architecture”Inference uses a trained model and input data to produce results. The deployment location depends on model size and user demand.
Inference models may run:
- On mobile devices or laptops
- At edge locations
- In enterprise data centers
- In cloud data centers
- Co-located with training data centers
Most inference data centers do not require strict rail alignment because inference can often run on one GPU or a small number of GPUs. The network usually follows a Clos-based design similar to normal data center networks.
Multi-node inference is a special case. If inference spans many GPUs or nodes, RDMA and backend design choices may become relevant again.
Multi-Planar Scale-Out Architecture
Section titled “Multi-Planar Scale-Out Architecture”Why Multi-Planar Designs Exist
Section titled “Why Multi-Planar Designs Exist”Traditional three-tier networks hit practical limits when AI clusters grow toward hundreds of thousands of GPUs.
Problems with very large single-plane fabrics:
- A failure can affect a huge fabric domain.
- Five-stage designs add extra hops.
- Latency-sensitive AI workloads can suffer.
- Operational blast radius becomes large.
- Cabling and optics become difficult to manage.
Multi-planar architecture addresses this by replacing one massive backend fabric with multiple independent two-tier fabric planes.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart LR
classDef host fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef nic fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef plane1 fill:#3b2f20,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef plane2 fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef plane3 fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef plane4 fill:#173f32,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef fabric fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef note fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
SRC[Source GPU Server]:::host
SNIC[800G NIC<br/>packet spray + sequencing]:::nic
DNIC[Destination NIC<br/>reorder + coalesce]:::nic
DST[Destination GPU Server]:::host
subgraph FP1["Fabric Plane 1: independent 2-tier Clos"]
direction TB
P1L[FP1 leaf]:::plane1
P1S[FP1 spine]:::fabric
P1L --> P1S
P1S --> P1L
end
subgraph FP2["Fabric Plane 2: independent 2-tier Clos"]
direction TB
P2L[FP2 leaf]:::plane2
P2S[FP2 spine]:::fabric
P2L --> P2S
P2S --> P2L
end
subgraph FP3["Fabric Plane 3: independent 2-tier Clos"]
direction TB
P3L[FP3 leaf]:::plane3
P3S[FP3 spine]:::fabric
P3L --> P3S
P3S --> P3L
end
subgraph FP4["Fabric Plane 4: independent 2-tier Clos"]
direction TB
P4L[FP4 leaf]:::plane4
P4S[FP4 spine]:::fabric
P4L --> P4S
P4S --> P4L
end
APP[Application still sees<br/>one logical RDMA flow]:::note
BR[800G split into<br/>4 x 200G plane links]:::note
SRC --> SNIC
SNIC -.-> BR
SNIC -->|200G slice| P1L
P1L --> DNIC
SNIC -->|200G slice| P2L
P2L --> DNIC
SNIC -->|200G slice| P3L
P3L --> DNIC
SNIC -->|200G slice| P4L
P4L --> DNIC
DNIC --> DST
APP -.->|ordering hidden below app| SNIC
APP -.->|in-order completion| DNIC
The application can still see one logical flow, while the NIC and host software distribute packets across multiple planes and reassemble them at the destination.
Breakout Cables and Packet Spraying
Section titled “Breakout Cables and Packet Spraying”The chapter gives an example where an 800G NIC breaks out into 4 x 200G links, each connected to a different fabric plane.
This creates several effects:
- One logical NIC can use multiple physical planes.
- A leaf switch can support more GPU connections.
- The NIC can spray packets across independent paths.
- The receiver NIC reorders and coalesces packets before presenting data to the application.
- RDMA still requires in-order delivery at the application layer, so reassembly is critical.
Multi-Domain Designs and Super-Spines
Section titled “Multi-Domain Designs and Super-Spines”Large multi-planar deployments may still need super-spines to connect multiple multi-planar domains.
Examples:
- Two fabric planes with two rails per plane
- Dual-planar domains interconnected by super-spines
- Four-plane designs where packets are sprayed across all planes
Important design points:
- Some server pairs can communicate within one plane without using super-spines.
- Other server pairs must cross the super-spine layer.
- Scheduling collective jobs with topology awareness can reduce the observed latency penalty.
- Reliability improves because multiple planes provide independent paths.
Cabling and Optics
Section titled “Cabling and Optics”Multi-planar designs can increase cabling complexity because each host and ToR port may connect to multiple planes.
Mitigation options include:
- Shuffle cables to consolidate and internally map fiber bundles
- Breakout cables for NIC-to-plane connectivity
- Linear Pluggable Optics, LPO
- Linear Receive Optics, LRO
The chapter notes that LPO and LRO can reduce power by removing some or all DSP functionality from optical modules, relying more on NIC and switch SERDES capabilities. Lower optics power also reduces heat and cooling demand, freeing more facility power for GPU compute.
Additional Design Notes
Section titled “Additional Design Notes”The PDF explains the architectural options. This section adds a more practical design lens: how to choose, calculate, validate, and track where Ethernet-based AI fabrics are going.
Design Decision Matrix
Section titled “Design Decision Matrix”Different AI fabric designs optimize different constraints. A good design starts by identifying the dominant constraint: JCT, cabling, fault isolation, power, optics, rack layout, or operational simplicity.
| Design | Best Fit | Avoid When | Main Risk |
|---|---|---|---|
| ROD | Large training clusters, predictable NCCL topology, strong rail isolation | Port/cabling budget is too tight | Physical complexity |
| RUD | Smaller clusters, simplified cabling, chassis or fat-leaf designs | Rail fault isolation is critical | Larger shared-fate domain |
| Rail-only | Workloads rarely need inter-rail fabric communication | Collectives frequently cross rails | Workload dependency |
| Three-stage Clos | Small to medium clusters with non-blocking leaf-spine design | Cluster scale exceeds port/radix limits | Spine count and cabling growth |
| Five-stage / Seven-stage Clos | Very large clusters such as 32K+ GPUs | Low latency is more important than raw scale | More hops and upper-layer congestion |
| Scheduled fabric | Very large, congestion-sensitive AI fabrics | Vendor lock-in or operational complexity is unacceptable | Architecture dependence |
| Multi-planar | Very large scale, higher reliability, NIC-level packet spraying | NIC/host reordering and observability are immature | Debugging complexity |
The important question is not “Which topology is best?” The better question is “Which bottleneck is this design trying to remove?”
Scale-Up, Scale-Out, and Scale-Across
Section titled “Scale-Up, Scale-Out, and Scale-Across”AI data center networks are easier to reason about when split into three scaling domains.
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
classDef gpu fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef server fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef fabric fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef site fill:#5a3520,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef wan fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef limit fill:#62164d,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
subgraph SA["Scale-Across: multiple sites"]
direction LR
DC1["AI data center 1"]:::site
DCI["DCI / WAN-aware AI fabric<br/>distance, jitter, failure domain"]:::wan
DC2["AI data center 2"]:::site
DC1 <--> DCI
DCI <--> DC2
end
subgraph SO["Scale-Out: one data center cluster"]
direction TB
FAB["Training fabric<br/>rails / leaf-spine / RDMA"]:::fabric
S1["GPU server 1"]:::server
S2["GPU server 2"]:::server
S3["GPU server N"]:::server
S1 <--> FAB
S2 <--> FAB
S3 <--> FAB
end
subgraph SU["Scale-Up: inside one GPU server"]
direction LR
G0["GPU0"]:::gpu
NV["NVLink / NVSwitch / PCIe<br/>internal GPU domain"]:::server
G7["GPU7"]:::gpu
G0 <--> NV
NV <--> G7
end
L1["Scale-up limit:<br/>server internal GPU fabric"]:::limit
L2["Scale-out limit:<br/>power, cooling, optics, cabling"]:::limit
L3["Scale-across limit:<br/>distance, jitter, site failure domains"]:::limit
SU --> L1
SU --> SO
SO --> L2
SO --> SA
SA --> L3
| Scale Model | Boundary | Typical Technology | Network Concern |
|---|---|---|---|
| Scale-up | Inside a GPU server or rack-scale system | NVLink, NVSwitch, PCIe | GPU locality and internal bandwidth |
| Scale-out | Across many GPU servers in one data center | InfiniBand, RoCEv2, Spectrum-X Ethernet, Clos, ROD/RUD | JCT, RDMA, congestion, rail design |
| Scale-across | Across multiple data centers or sites | DCI, WAN-aware Ethernet, distributed AI fabric | Distance, jitter, telemetry, long-distance congestion control |
Traditional AI cluster design focuses on scale-up and scale-out. As single facilities hit power, cooling, land, and capacity limits, scale-across becomes more important.
Oversubscription Calculation
Section titled “Oversubscription Calculation”Oversubscription should be calculated explicitly for each fabric layer. AI training fabrics often target 1:1 bandwidth in the backend because synchronized GPU traffic can quickly expose bottlenecks.
Server-facing bandwidth = number_of_downlinks x link_speedFabric-facing bandwidth = number_of_uplinks x link_speedOversubscription ratio = server-facing bandwidth : fabric-facing bandwidthExample with a 64-port 400G leaf:
32 x 400G downlinks = 12.8 Tbps32 x 400G uplinks = 12.8 TbpsOversubscription = 1:1Example with fewer uplinks:
48 x 400G downlinks = 19.2 Tbps16 x 400G uplinks = 6.4 TbpsOversubscription = 3:1In AI training, oversubscription is not just a cost optimization. It changes queue behavior, ECN marking, PFC risk, and ultimately Job Completion Time.
Operational Validation Checklist
Section titled “Operational Validation Checklist”A design is not finished when the topology diagram looks correct. It must be validated against traffic patterns that resemble real training and inference workloads.
| Area | What to Check | Why It Matters |
|---|---|---|
| NCCL performance | AllReduce, AllGather, ReduceScatter, AlltoAll benchmarks | Confirms collective communication behavior |
| Rail balance | Per-rail throughput and utilization | Finds rail hot spots and bad placement |
| Link utilization | Leaf, spine, and super-spine utilization | Confirms ECMP/DLB/packet spraying effectiveness |
| ECN | ECN marking rate and queue thresholds | Shows early congestion signals |
| PFC | Pause frame count and pause duration | Detects lossless Ethernet stress and congestion spreading |
| Drops/retransmits | Packet drops, CNPs, retransmission counters | Identifies hidden loss or transport instability |
| Tail latency | p95/p99/p999 latency during collectives | AI jobs are often gated by slowest participants |
| Failure handling | Leaf, spine, NIC, and link failure tests | Confirms blast radius and convergence behavior |
| Job placement | GPU placement vs rail/topology locality | Prevents scheduler decisions from fighting the network |
| Telemetry | Per-queue, per-flow, per-port observability | Makes congestion root cause analysis possible |
Suggested validation flow:
%%{init: {"theme": "base", "themeVariables": {"background": "#171717", "primaryColor": "#232323", "primaryTextColor": "#f5f5f5", "primaryBorderColor": "#d0d0d0", "lineColor": "#cfcfcf", "fontFamily": "Inter, Arial, sans-serif"}}}%%
flowchart TB
classDef model fill:#3b2f20,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef test fill:#173f32,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef signal fill:#52676b,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef decision fill:#173f32,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef fail fill:#173f32,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
classDef pass fill:#3b2f20,stroke:#d0d0d0,color:#f5f5f5,stroke-width:2px;
C[1. Capacity model<br/>downlinks, uplinks, radix, oversubscription]:::model
W[2. Workload model<br/>NCCL collectives, storage, inference, incast]:::model
B[3. Baseline counters<br/>idle ECN, PFC, drops, queue depth]:::test
T[4. Load validation<br/>NCCL / RDMA / mixed traffic]:::test
S[5. Congestion signals<br/>ECN, CNP, PFC, drops, p99 latency, JCT]:::signal
D{6. Does measured behavior<br/>match the capacity model?}:::decision
P[Accept design<br/>document operating envelope]:::pass
R[Revise design<br/>uplinks, placement, QoS, load balancing, pod size]:::fail
C --> W
W --> B
B --> T
T --> S
S --> D
D -->|Yes| P
D -->|No| R
R --> C
RoCEv2 and UEC/UET Roadmap
Section titled “RoCEv2 and UEC/UET Roadmap”Most Ethernet AI training fabrics today are designed around RoCEv2 plus congestion mechanisms such as ECN, PFC, CNP, and DCQCN. This works, but it also exposes several pain points at very large scale:
- ECMP can be weak when traffic has low entropy.
- PFC can prevent drops but may spread congestion.
- Ordered RDMA semantics make packet spraying harder.
- Incast and synchronized collectives can create short, intense congestion events.
- Debugging end-to-end congestion requires deep telemetry across NICs, switches, and hosts.
The Ultra Ethernet Consortium, UEC, is working on Ultra Ethernet Transport, UET, as an Ethernet-based stack optimized for AI and HPC. UEC 1.0 was announced in 2025 and focuses on open, interoperable high-performance Ethernet.
Key ideas to watch:
| Area | Direction |
|---|---|
| Multipathing | Packet spraying across multiple paths instead of relying only on ECMP flow hashing |
| Ordering | More flexible delivery models for workloads that can tolerate reordering |
| Congestion control | Sender and receiver mechanisms optimized for microsecond-scale AI fabrics |
| Packet trimming | Truncate packets under congestion to give fast congestion/loss signals instead of silent drops |
| Security | Transport security and isolation for hosted or multi-tenant AI environments |
| APIs | libfabric-based APIs for AI/HPC communication semantics |
Practical view: RoCEv2 remains important for current deployments, but UEC/UET is worth tracking for future Ethernet AI fabrics because it directly targets packet spraying, congestion control, ordering, and interoperability at AI scale.
Chapter Summary
Section titled “Chapter Summary”AI network design requires matching the topology to the workload, scale, power budget, and operational model.
The main takeaways:
- AI data centers use different fabrics for storage, training, and inference.
- Training fabrics are dominated by GPU-to-GPU east-west traffic.
- ROD gives predictable rail alignment and strong isolation, but increases cabling and port demands.
- RUD simplifies some physical design choices, but can increase shared fate and requires careful path control.
- Rack design directly affects power, cooling, cable length, and optics choices.
- Clos remains the default topology, but extreme AI scale can require five-stage, seven-stage, chassis-based, or oversubscribed designs.
- Dragonfly and Torus can reduce hop count or port requirements for selected workloads, but increase routing and placement complexity.
- Scheduled fabric and VOQ aim to improve congestion handling and link utilization.
- Multi-planar fabrics split a huge backend network into independent planes and rely on NIC-level packet spraying and reassembly.
Key Terms
Section titled “Key Terms”| Term | Meaning |
|---|---|
| ROD | Rail-Optimized Design; one GPU/NIC maps to one rail/leaf |
| RUD | Rail-Unified Design; multiple GPUs may connect to one leaf |
| Rail | A network path associated with the same GPU/NIC position across servers |
| Row / Stripe | A set of leaf switches supporting multiple rails across servers |
| Intra-rail | Communication within the same GPU-number rail |
| Inter-rail | Communication between different rails, often through spine switches |
| Rail-only design | Design where the external fabric does not support inter-rail traffic |
| Clos | Leaf-spine or multi-stage fat-tree topology |
| Block / Brick | A scale unit made from rows and spines, often connected by super-spines |
| Scheduled fabric | Fabric that splits packets into cells and schedules them across links |
| VOQ | Virtual Output Queueing; separate queues per output to reduce head-of-line blocking |
| Dragonfly | Hierarchical group-based topology with mesh-like interconnects |
| Torus | Neighbor-connected topology in one, two, or three dimensions |
| Multi-planar | Design using multiple independent fabric planes for scale and reliability |
| Shuffle cable | Cabling system that bundles and internally maps fibers for large cluster connectivity |
| LPO | Linear Pluggable Optics |
| LRO | Linear Receive Optics |
1. What are the three main stages of AI/ML workload processing, and how do they map to storage, training, and inference fabrics?
Section titled “1. What are the three main stages of AI/ML workload processing, and how do they map to storage, training, and inference fabrics?”At a high level, AI/ML processing has three stages: data gathering and preprocessing, model selection and training, and deployment and monitoring.
From an infrastructure point of view, these stages map to three different traffic domains. Data gathering and preprocessing primarily stress the storage fabric because large data sets must be ingested, cleaned, tagged, and later read by training jobs. Model training stresses the training fabric because GPUs exchange gradients, parameters, activations, and optimizer state through east-west RDMA traffic. Deployment and monitoring stress the inference or frontend fabric because trained models serve user requests, APIs, telemetry, and production traffic.
In an interview, I would emphasize that these fabrics should not be treated as one generic network. Storage traffic, training traffic, and inference traffic have different failure modes and performance metrics. Storage cares about sustained throughput and checkpoint reliability. Training cares about Job Completion Time, GPU utilization, congestion, and tail latency across collectives. Inference cares about request latency, throughput, availability, and sometimes Time to First Token.
The design mistake is to collapse all three domains without understanding contention. It can be acceptable in a small deployment, but at scale it becomes hard to reason about congestion, QoS, blast radius, and capacity planning.
2. Why does distributed training need a specialized backend fabric instead of a normal enterprise data center network?
Section titled “2. Why does distributed training need a specialized backend fabric instead of a normal enterprise data center network?”Distributed training is dominated by synchronized east-west GPU-to-GPU communication. That traffic is high bandwidth, bursty, often long lived, and frequently tied to collective operations such as AllReduce, AllGather, ReduceScatter, and AlltoAll. A normal enterprise network is usually optimized for mixed client-server traffic, oversubscription, north-south access, and general availability. It is not usually designed to keep thousands of GPUs moving in lockstep.
The key issue is that the slowest participant can gate the whole training step. If one GPU is delayed because its flow hit a congested link, a bad ECMP hash, PFC pause, or incast event, the whole collective can slow down. That means network tail latency becomes GPU idle time, and GPU idle time becomes longer JCT.
A proper backend training fabric therefore needs high bisection bandwidth, low or controlled oversubscription, predictable rail topology, RDMA support, congestion visibility, ECN/PFC/DCQCN or equivalent mechanisms, and topology-aware job placement. It also needs operational telemetry at the queue, link, NIC, and flow level.
The practical answer is: a normal data center fabric moves packets; an AI backend fabric protects accelerator utilization.
3. How does Rail-Optimized Design differ from Rail-Unified Design?
Section titled “3. How does Rail-Optimized Design differ from Rail-Unified Design?”Rail-Optimized Design, ROD, maps each GPU/NIC position to its own rail or leaf. In an 8-GPU server, GPU0/NIC0 connects to Rail 0, GPU1/NIC1 connects to Rail 1, and so on. Across servers, the same GPU index lands on the same rail. This gives predictable paths, strong rail isolation, and low-latency intra-rail communication.
Rail-Unified Design, RUD, groups multiple GPU/NIC connections from the same server onto fewer leaf switches. For example, GPUs 0-3 might connect to Leaf A and GPUs 4-7 to Leaf B. This can simplify cabling and reduce some physical complexity, but it increases the failure domain and requires more careful traffic segregation and deterministic path forwarding.
The trade-off is straightforward:
| Design | Optimizes For | Pays With |
|---|---|---|
| ROD | Performance, rail isolation, predictable topology | More cables, ports, and rack complexity |
| RUD | Cabling simplicity and potentially lower physical cost | Larger shared fate and more path-control complexity |
If I were designing for large-scale training, I would start with ROD unless there is a strong physical, cost, or platform reason not to. If I were designing a smaller cluster or using a chassis/fat-leaf design where cabling simplicity matters more, I would evaluate RUD carefully.
4. Why is intra-rail communication lower latency than inter-rail communication in ROD?
Section titled “4. Why is intra-rail communication lower latency than inter-rail communication in ROD?”Intra-rail communication stays within the same GPU index across servers. For example, Server A GPU0 to Server B GPU0 can go through Rail 0 and often only needs the rail leaf path. That is a short and predictable path.
Inter-rail communication crosses GPU indices. For example, Server A GPU0 to Server B GPU3 starts on Rail 0 but must reach Rail 3. That usually requires going up to the spine layer and then down to the destination rail. The path becomes leaf - spine - leaf instead of just leaf-local rail switching.
That extra hop matters because AI training traffic is not just sensitive to average latency. It is sensitive to synchronized delay and tail latency. A small amount of extra latency across many collective operations can accumulate into measurable JCT impact.
The operational consequence is that topology-aware placement and collective algorithm selection matter. If the scheduler places ranks without considering rail locality, it can turn what should be rail-local communication into inter-rail traffic and unnecessarily load the spine layer.
5. What limits the scale of a three-stage Clos fabric for large GPU clusters?
Section titled “5. What limits the scale of a three-stage Clos fabric for large GPU clusters?”A three-stage Clos, leaf - spine - leaf, is simple and effective up to a point. The scale limit comes from switch radix, port count, uplink/downlink allocation, cabling, optics, power, and the number of equal-cost paths the fabric can manage cleanly.
For example, if a 64-port 400G leaf uses 32 ports down to servers and 32 ports up to spines, one row can support a certain number of GPU-facing links at 1:1 oversubscription. To add more GPUs, you add more rows, more leaves, and more spines. Eventually, the spine layer becomes physically and operationally large. You either run out of practical spine ports, create too many devices to manage, or introduce cabling and optics complexity that becomes hard to operate.
At large scale, the issue is not only “Can I draw the topology?” It is whether the topology can sustain collective traffic with predictable performance, whether ECMP or load balancing remains effective, whether failure domains are acceptable, and whether the physical build is feasible.
That is why designs move toward chassis-based spines, five-stage Clos, seven-stage Clos, blocks/bricks, or alternative topologies when GPU counts become very large.
6. Why might a five-stage or seven-stage Clos design introduce new congestion and latency concerns?
Section titled “6. Why might a five-stage or seven-stage Clos design introduce new congestion and latency concerns?”Five-stage and seven-stage Clos designs add scale by adding hierarchy. That solves port-count limits, but it also adds hops. Every extra stage adds serialization, forwarding latency, optics, cables, buffers, queues, and failure points.
The bigger concern is the upper layers. In a five-stage Clos, block-to-block traffic crosses the super-spine layer. If that layer is oversubscribed, congestion can become concentrated there. This is especially risky for AI training because collectives can create synchronized bursts across many endpoints at the same time.
There is also a placement problem. If a job fits inside one block, traffic can remain relatively local. If the job is spread across blocks, it may hit the super-spine frequently. Two jobs with the same GPU count can have different performance depending on placement.
In practice, five-stage and seven-stage designs require stronger telemetry, congestion control, job scheduling discipline, and capacity modeling. They are not bad designs, but they move the hard problem from “how do I connect enough ports?” to “how do I keep upper-stage congestion from dominating JCT?“
7. What are the physical trade-offs between ToR, MoR, and EoR rack designs?
Section titled “7. What are the physical trade-offs between ToR, MoR, and EoR rack designs?”The main trade-off is cable length versus rack power, cooling, and operational centralization.
Top-of-Rack, ToR, places leaf switches in the server racks. It shortens local cables and can make DAC or AEC practical, which helps cost and signal quality. The downside is that switch power and heat are inside already power-dense GPU racks. For AI racks, that matters because a few GPU servers can already push the rack close to facility limits.
Middle-of-Row, MoR, centralizes network gear near the middle of the row. It reduces switch load inside server racks while keeping cable lengths moderate. It is often a reasonable compromise, but cable planning becomes more complex than ToR.
End-of-Row, EoR, centralizes network gear at the end of the row. It keeps server racks cleaner from a switching power/cooling perspective, but cable lengths are longest and optics/cabling choices become more important.
The design decision should consider rack power budget, airflow, cable type, maximum cable length, serviceability, rail design, and failure domains. In AI data centers, physical design is part of network design. Treating cabling and cooling as an afterthought is how good logical designs become bad deployments.
8. How does scheduled fabric use cells and VOQ to reduce congestion problems?
Section titled “8. How does scheduled fabric use cells and VOQ to reduce congestion problems?”Scheduled fabric treats the fabric more like a distributed chassis. The ingress leaf behaves like a line card, the spine layer behaves like a backplane, and packets are split into smaller cells before crossing the fabric. These cells can be scheduled and spread across multiple fabric links, then reassembled at the egress leaf.
Virtual Output Queueing, VOQ, is important because it avoids head-of-line blocking. Instead of one congested egress destination blocking unrelated traffic, the ingress side maintains separate queues per destination or egress. A scheduler decides when and where cells should move.
The benefit is more deterministic congestion handling and better link utilization. Instead of relying only on packet-level switching and reactive congestion signals, the fabric can schedule work across the internal fabric more deliberately.
The trade-off is complexity and dependency on specific silicon and architecture. Scheduled fabric can be very powerful for bursty AI workloads, but it must be evaluated for failure handling, observability, interoperability, and operational model. It is closer to building a distributed system than just deploying a set of independent Ethernet switches.
9. When might Dragonfly or Torus be considered instead of Clos?
Section titled “9. When might Dragonfly or Torus be considered instead of Clos?”Clos is the default because it is well understood, IP-friendly, and operationally familiar. I would consider Dragonfly or Torus only when the workload and scale justify the extra topology and routing complexity.
Dragonfly is attractive when the goal is to reduce network diameter at very large scale. It connects groups or blocks with global links and can reduce hop count compared to a very deep Clos. This can help latency and cost, but it usually requires more careful routing, adaptive path selection, and failure-domain thinking.
Torus is attractive when traffic locality is predictable. A 1D, 2D, or 3D torus can be cost-effective because each node connects to a small number of neighbors. It works well when application placement can keep communication near neighboring nodes. It is less attractive for arbitrary all-to-all traffic where distant nodes communicate frequently.
The senior-engineer answer is: do not choose Dragonfly or Torus because they look elegant. Choose them only when the application communication pattern, scheduler, routing stack, and operational team can exploit the topology. Otherwise, a well-built Clos is usually the safer design.
10. How does a multi-planar architecture use breakout links and NIC packet spraying to improve scale and reliability?
Section titled “10. How does a multi-planar architecture use breakout links and NIC packet spraying to improve scale and reliability?”Multi-planar architecture splits one large backend fabric into multiple independent fabric planes. Instead of connecting a GPU server NIC to a single fabric path, the NIC can break out a high-speed port, for example 800G into 4 x 200G, and connect each breakout link to a different plane.
The NIC or host networking stack sprays packets across those planes. The destination NIC receives packets from multiple independent paths, reorders or coalesces them, and presents an in-order completion to the application. From the application perspective, it can still look like one logical RDMA flow.
This improves scale because each plane is smaller and simpler than one massive fabric. It improves reliability because a failure in one plane does not necessarily remove connectivity; it may reduce capacity while other planes continue forwarding. It can also improve load distribution because traffic is not locked to one ECMP-selected path.
The main engineering challenge is observability and correctness. Packet spraying creates reordering. Reordering requires NIC/host support. Troubleshooting now spans host software, NIC firmware, fabric planes, telemetry, and application behavior. Multi-planar designs are powerful, but they demand disciplined validation and operations.
In practice, I would validate this architecture with NCCL benchmarks, failure injection, per-plane utilization, reordering counters, ECN/PFC counters, and job-level JCT measurements before trusting it for production-scale training.
References
Section titled “References”- NVIDIA Enterprise Reference Architectures
- NVIDIA HGX AI Factory: Networking Logical Architecture